Oct 19, 2026
MPMC POWERTECH CORP., established in 2008 and headquartered in Shanghai Pudong, manufactures the BCH Series mobile BESS charger, a battery-integrated mobile charging station that brings fast DC charging to electric excavators, wheel loaders, dumpers and site vehicles wherever a construction project needs it. As European contractors electrify their machinery to deliver zero-emission sites, the BCH gives them dependable charging from day one of a project, with no permanent grid connection required. This article covers the BCH platform for construction sites, MPMC's 2 MWh off-grid construction charging project in Norway, the energy sources a site can use, and how MPMC supports contractors and equipment dealers across Europe.
MPMC BCH-275-200 mobile BESS charger on a construction site, ready to charge electric machinery without a grid connection.A construction site is temporary by nature, so a mobile charger that arrives, works and moves on with the project is the natural partner for an electric machinery fleet. MPMC's BCH Series stores energy from the grid, a generator, battery storage or solar PV and delivers fast DC charging to electric vehicles, trucks and construction machinery, while also supplying AC power for site cabins, tools and lighting. Each unit reaches full operational status within 24 hours, so charging is ready as soon as the machines are.
BCH units use fully sealed, liquid-cooled blade LFP battery packs that keep dust out, with a high-strength sandwich structure tested for fire, water immersion, high-impact collision and crushing. Enclosures carry C4 industrial anti-corrosion coating, with C5 available on the BCH-800-600 and BCH-500-1000. The BCH-275-200 rides on a 3.5-tonne heavy-duty trailer with integrated forklift pockets for easy repositioning as work zones shift, while the larger models are housed in heavy-duty enclosures, with the BCH-500-1000 built into a 20-foot container for long-duration site work.
MPMC's Norway project shows the BCH platform at work on a demanding European site. Delivered as a rental construction heavy machinery charging system, the 2 MWh BCH installation uses units rated at 500 kW and 1,000 kWh each, with CCS2 charging output of 360 kW at 400 A, and charges electric construction machinery fully off-grid with no diesel generator. Its rental structure also shows how well the BCH suits project-based procurement, which is how much European construction equipment is supplied.
Table 1. MPMC BCH Series models for construction sites
| Model | DC charging output | Storage | Charging guns | Format and typical construction use |
|---|---|---|---|---|
|
BCH-80-70 |
80 kW |
70 kWh |
1 x CCS2, 260 A |
880 kg compact unit; light site vehicles and compact machinery |
|
BCH-275-200 |
150 kW |
203.5 kWh |
2 x CCS2, 250 A |
3.5 t trailer, forklift pockets; mid-size machinery and site EVs |
|
BCH-600-400 |
400 kW |
407 kWh |
2 x CCS2, 350 A |
Heavy-duty enclosure, 8,300 kg; heavy machinery and electric tippers |
|
BCH-800-600 |
600 kW |
610.6 kWh |
2 x CCS2, 350 A |
1C charge and discharge; high-intensity heavy machinery charging |
|
BCH-500-1000 |
500 kW |
1,075 kWh |
2 x CCS2, 350 A |
20' GP container; large sites, mines and remote power hubs |
MPMC BCH-275-200 on its trailer, charging two electric vehicles at once through dual CCS2 charging guns.BCH units accept AC input from the grid, generator sets or solar PV, with rated AC input of 80 kW on the BCH-275-200, 280 kW on the BCH-600-400 and BCH-800-600, and 560 kW on the BCH-500-1000. The onboard battery then delivers charging power above the incoming supply, so a modest site connection or a right-sized generator can support high-power machinery charging. On remote sites, a BCH pairs naturally with an MPMC containerised generator set or GSB hybrid power station, and the BCH-275-200 can also recharge through its CCS2 DC input from a fast-charging station in about one hour.
Grid infrastructure often arrives part-way through a build. Because the same BCH unit accepts grid, generator or solar input, it simply changes energy source when the connection is ready, carrying the contractor's charging set-up through every phase of the project and on to the next site. Contractors keep one familiar system, one monitoring platform and one service partner from groundworks to handover.
BCH-275-200 and larger models include CE-certified aerosol fire protection, and MPMC's product certifications include CE, UN38.3 for battery transport, TUV and SGS. At company level MPMC holds ISO 9001:2015, ISO 45001 and ISO 14001 and operates a CNAS-accredited testing centre in Haimen, Jiangsu. Every BCH charging model has an EMS with 4G connectivity, OCPP 1.6 and an open, cloud-ready API, giving site managers full remote monitoring and control, while MPMC provides remote diagnostics through its SCADA/EMS platform and on-site commissioning by its own engineers.
Table 2. How the BCH Series meets construction-site requirements
| Site requirement | BCH capability | Benefit to the contractor |
|---|---|---|
|
Charging with no grid on site |
Grid, genset, solar or stored-battery operation; Norway 2 MWh off-grid reference |
Electric machinery working from the first day |
|
Fast mobilisation |
Full operational status within 24 hours |
No waiting for civil works or grid approval |
|
Rugged site conditions |
Sealed liquid-cooled packs; C4 coating, C5 optional on large models |
Dependable operation in dust, rain and cold |
|
Relocation as work zones move |
3.5 t trailer (BCH-275-200); heavy-duty enclosures and 20' container (BCH-500-1000) |
Charging follows the work across the site |
|
Site power for other loads |
AC output from 125 kW (BCH-275-200) to 600 kW (BCH-800-600), 500 kW (BCH-500-1000) |
One unit powers cabins, tools and lighting too |
|
Remote oversight |
4G EMS, OCPP 1.6, open API, remote command |
Full visibility without a dedicated technician |
European contractors often rent or lease machinery for the length of a project, and the BCH fits the same model. A rental company or new-energy construction equipment dealer can supply the electric machines and the BCH charger as one package, move both to the next project when the job is done, and keep the charger earning across many sites. Because MPMC focuses on manufacturing, it partners with rental companies and dealers who build and operate their own rental offers, rather than competing with them for site work.
Battery charging is silent at the point of use, which helps contractors working near homes, schools and offices or under local noise limits. MPMC's UK data shows how much cleaner battery charging can be: a BCH-275-200 that delivered 3,457 kWh replaced the 976 litres of diesel an equivalent 150 kW generator would have burned, and solar-supplied BCH charging produces around 22 times less lifecycle CO2 than diesel generation for the same output.
• Total the daily energy needed by every electric machine on site
• Choose BCH models with headroom for machinery you plan to add
• Select the starting energy source: grid, generator, solar or battery
• Plan the switch to grid power if a connection is due during the build
• Confirm the transport format (trailer or container) for your site access
• Set up remote monitoring through the 4G EMS or your own platform via OCPP 1.6
• Arrange on-site commissioning with MPMC's engineers
• Contact MPMC at sales@mpmc-china.com or WhatsApp +86 150 0085 4420 for a site proposal
Yes. MPMC's Norway project charges electric construction machinery fully off-grid with a 2 MWh BCH system and no diesel generator, using CCS2 output of 360 kW at 400 A.
MPMC's product certifications include CE, UN38.3 for battery transport, TUV and SGS, and BCH-275-200 and larger models have CE-certified aerosol fire protection. Company-level certifications include ISO 9001:2015, ISO 45001 and ISO 14001.
A BCH can be charged by an MPMC containerised generator set, a GSB hybrid solar-diesel-battery station or solar PV, and the onboard battery then delivers fast DC charging to the machinery.
Every BCH charging model has an EMS with 4G connectivity, OCPP 1.6 and an open API for remote monitoring and command, and MPMC provides remote diagnostics through its SCADA/EMS cloud platform.
Yes. BCH units accept grid, generator or solar input, so the same unit switches to the grid once a connection is available and continues serving the site through every phase.